| Measurement modes |
Transmission(dB),return loss(dB),SWR(linearSWR),optiona group delay(ns),power(dBm)precision return loss(dB) and optionaldistance-to-fault |
| Dynamic range |
-55 to +16dBm,autozeroing with DC detection |
| Inputs |
Three,two standard inputs,A and B,with optionathird reference channel,R(Option 5) |
| Display channels |
Two channels are used to select and simultaneouslydisplay any two inputs fromA,B,or R.The inputs can also be displayed asratios A/R or B/R. |
| Scale resolution |
0.1 to 10dB(m) per division in 0.1dB steps |
| Cursor functions |
Searches for trace maximum,minimum,dB level,dBbandwidth,next marker and active marker |
| Averaging |
2,4,8,16,32,64,128,or 256 |
| Limit lines |
Two limit ines,either single value or multilevel segmented,for each trace.Segmented lines may be made from up to 10individually editable segments. |
| Auto-zero |
Performs an AC modulation cycle and lowlevel calibration during sweeper ratrace |
| Save/Recall |
Thirteen sets of front panel set-ups andthirteen sets of trace memory can be stored in non-volatile instrument memory. |
| Trace mask |
A swept frequency measurement can be storedto a graticule trace mask for visual comparison to later measurements. |
| Disk drive |
Built-in 3.5 inch,1.44MB floppy disk drive |
| Autosave |
Automatically increments the trace datafile name and reference number during successive data storage operationsto the DOS disk |
| Source |
Frequency range |
1Mhz to0GHz,model dependent |
| Alternate sweep |
Sweep alternately between frequenc yrangesset differently for channel 1 and channel 2 |
| CW |
Provides single frequency output(both channelsturned off) |
| Frequency resolution |
Rf Model(54107A,54109A,54111A):10kHz,Microwavemodels:100khz |
| Output power |
Maximum guaranteed levelled output poweris model dependent. |
| Reverse power protection |
UP to 5 Watts.Limited to 1 Watt with attenuatoroption |
Appli- cation function |
Min/Max hold |
Save the minimum and maximum values of successivesweeps or the combination of the two |
| Cursor functions |
Automatic cursor seach updates the bandwidth,minimum,ormaximum levels of the displayed trace. |
| Compression test automation |
Determines the gain compression point overthe operating freqeuncy range of an ampliffier by successively incrementingthe source power and measuring the amount of compression until a preset"X"dBlimit is exceeded. |
| Self test |
Performs a self test every time power isapplied or when SELF TEST pushbutton is pressed.If an error is detected,adiagnostic code appears,identifying the cause and location of the error. |
| General |
Operating temperature |
0°to 50℃ |
| Power |
48 to 400Hz,300VA |
| Mass |
18kg(39lb.) |
| Printer |
Parallel printer interface is compatiblewith the Canon BJ30,Bj200e,and most Epson FX-compatible printers. |
| Transit case |
Hard shell case with custom foam inserts,PN:760-183 |
| EMC |
Meets European community requirements forCE marking |